Weber Number
The Weber number compares the disruptive inertial forces in a flow to the cohesive surface-tension forces that hold a droplet or bubble together. At low We, surface tension wins and drops stay intact. At high We, inertial forces dominate and the droplet shatters.
We = ρv²L / σ
How It Works
The Weber number compares the disruptive inertial forces in a flow to the cohesive surface-tension forces that hold a droplet or bubble together. At low We, surface tension wins and drops stay intact. At high We, inertial forces dominate and the droplet deforms, oscillates, or shatters into smaller fragments. This makes We the key parameter for fuel injector design, spray coating, inkjet printing, and any process where controlling droplet size matters. For a drop broken up by a gas stream, ρ is the gas density and v is the drop's speed relative to the gas; inkjet drop formation and drop impact use the liquid's own density instead.
Example Problem
A 2 mm water drop (σ = 0.0728 N/m) moves at 5 m/s relative to still air (ρ ≈ 1.2 kg/m³). What is its Weber number, and will the airflow break it apart?
- Breakup of a drop in a gas uses the gas Weber number, so ρ is the air's density: ρ = 1.2 kg/m³, v = 5 m/s, L = 0.002 m, σ = 0.0728 N/m
- Write the Weber number formula: We = ρv²L / σ
- Square the relative velocity: v² = 5² = 25 m²/s²
- Calculate the numerator: ρ × v² × L = 1.2 × 25 × 0.002 = 0.06 N/m
- Divide by surface tension: We = 0.06 / 0.0728 ≈ 0.82
- Interpret: a gas Weber number of 0.82 is far below the critical value of about 12, so the drop stays intact; it would need a relative speed of about 19 m/s, √(12 × 0.0728 / (1.2 × 0.002)), to reach the threshold
Using the water's density (998 kg/m³) by mistake gives We ≈ 685, the liquid Weber number, which cannot be compared with the ≈ 12 gas-Weber-number threshold.
When to Use Each Variable
- Solve for Weber Number — when you know density, velocity, length, and surface tension, e.g., checking whether a droplet will break up in a given flow.
- Solve for Density — when you know the Weber number, velocity, length, and surface tension, e.g., identifying what fluid density would produce a critical Weber number.
- Solve for Velocity — when you know the Weber number, density, length, and surface tension, e.g., finding the speed at which droplet breakup begins.
- Solve for Characteristic Length — when you know the Weber number, density, velocity, and surface tension, e.g., predicting the maximum stable droplet diameter in a spray.
- Solve for Surface Tension — when you know the Weber number, density, velocity, and length, e.g., determining what surface tension is needed to prevent atomization.
Key Concepts
The Weber number is a dimensionless ratio of disruptive inertial forces to restoring surface tension forces. Which density goes into it depends on the question. For a drop or bubble broken up by the flow around it, use the density of the surrounding fluid: the gas density for a drop in air, which gives the gas (aerodynamic) Weber number. For inkjet drop formation, drop impact, and the dripping check of a liquid jet, use the liquid's own density. Below the critical gas Weber number (about 12 for low-viscosity drops), surface tension holds a drop together. Above it, inertial forces overcome cohesion and the drop fragments through bag breakup, sheet stripping, or catastrophic breakup depending on how far We exceeds the threshold.
Applications
- Fuel injection: designing diesel and gasoline injectors to achieve fine atomization for efficient combustion
- Spray coating: controlling droplet size in paint, pharmaceutical, and agricultural spray systems
- Inkjet printing: tuning nozzle geometry and fluid properties for consistent droplet formation
- Meteorology: predicting raindrop breakup size limits in turbulent atmospheric flows
- Nuclear reactor safety: modeling coolant spray behavior during emergency core cooling
Common Mistakes
- Using the liquid's density in a drop-breakup check — the ≈ 12 threshold uses the surrounding gas density; with water's density a stable 2 mm drop at 5 m/s looks far past breakup (We ≈ 685 instead of about 0.82)
- Using the wrong characteristic length — for droplets it is the droplet diameter, for jets it is the jet diameter, and for films it is the film thickness
- Ignoring the Ohnesorge number — high-viscosity fluids resist breakup even at high Weber numbers because viscous forces dampen deformation
- Forgetting that surface tension decreases with temperature — the same flow conditions produce a higher Weber number in hot fluids
- Applying the critical gas Weber number for drops in a gas (about 12) to drops in a liquid — immiscible liquid-liquid systems have different breakup criteria
Frequently Asked Questions
What does the Weber number tell you about droplets and bubbles?
The Weber number indicates whether inertial forces or surface tension forces dominate a droplet or bubble. For a low-viscosity drop (Ohnesorge number below about 0.1) moving through a gas, with We computed from the gas density, a value below about 12 means the drop stays intact, though it may flatten or oscillate. At higher Weber numbers the momentum of the flow overwhelms surface tension and the drop deforms and eventually fragments into smaller drops. More viscous drops need a larger Weber number before they break up.
At what Weber number do droplets break apart?
For a liquid drop in a gas stream, breakup is judged with the gas Weber number, computed from the gas density, the drop's speed relative to the gas, and the drop diameter. Its critical value is about 12. Above that, Pilch and Erdman's classic regimes are bag breakup at We ≈ 12–50, bag-and-stamen breakup at 50–100, sheet stripping at 100–350, and catastrophic breakup above 350. The boundaries vary between studies and rise when viscosity matters (Ohnesorge number above about 0.1).
Should I use the gas density or the liquid density in the Weber number?
Match the density to the criterion you compare against. The ≈ 12 breakup threshold for a drop in a gas uses the gas density. Inkjet drop formation, drop impact, and the dripping check of a liquid jet use the liquid density, while the wind-induced and atomization regimes of a jet use the gas density. For water in air the two densities differ by about 830 times, so mixing them up shifts We by almost three orders of magnitude.
How is the Weber number used in fuel injector design?
Fuel injectors must atomize liquid fuel into fine droplets for efficient combustion. Atomization of a fuel jet is judged with the gas Weber number, computed from the cylinder gas density, the jet exit speed, and the nozzle diameter. Jets atomize once that number passes roughly 40, and diesel injectors typically run from several thousand to around 100,000. The liquid Weber number, computed with the fuel's own density, is tens of times larger again.
What is the difference between the Weber number and the Bond number?
The Weber number compares inertial forces to surface tension, while the Bond number (or Eotvos number) compares gravitational forces to surface tension. Use We when the flow velocity is the driving mechanism and Bo when gravity (buoyancy) drives the motion.
Does surface tension depend on temperature?
Yes. Surface tension generally decreases with increasing temperature. Water drops from 0.0756 N/m at 0°C to 0.0589 N/m at 100°C. This means the Weber number for the same flow conditions increases at higher temperatures, making atomization easier.
What role does the Ohnesorge number play alongside Weber number?
The Ohnesorge number (Oh) accounts for viscous damping that the Weber number ignores. High-viscosity fluids resist deformation even at high We. The breakup regime is best described on a We-Oh map: at low Oh, the critical gas Weber number is about 12, but at high Oh (above 0.1), significantly higher Weber numbers are needed for breakup.
References:
Lindeburg, Michael R. 1992. Engineer In Training Reference Manual. Professional Publication, Inc. 8th Edition (Weber number We = ρv²L/σ).
Jain, S. S., Tyagi, N., Prakash, R. S., Ravikrishna, R. V., and Tomar, G. 2019. Secondary breakup of drops at moderate Weber numbers: Effect of density ratio and Reynolds number. International Journal of Multiphase Flow, doi:10.1016/j.ijmultiphaseflow.2019.04.026 (aerodynamic Weber number defined with the gas density; critical value about 10–12; Pilch and Erdman breakup regimes, Table 1). https://arxiv.org/abs/1803.02989
Trettel, Ben. 2020. Reevaluating the jet breakup regime diagram. Atomization and Sprays 30, doi:10.31224/osf.io/nqhs5 (liquid and gas Weber numbers of a jet; dripping, wind-induced, and atomization boundaries, including Reitz's We_g = 40.3). https://engrxiv.org/preprint/view/740
Antonopoulou, E., Harlen, O. G., Walkley, M. A., and Kapur, N. 2020. Jetting behavior in drop-on-demand printing: Laboratory experiments and numerical simulations. Physical Review Fluids 5, 043603, doi:10.1103/PhysRevFluids.5.043603 (inkjet Weber number with the ink density; 5–10 m/s drop speeds; Ohnesorge and Reynolds limits for satellite-free drops). https://eprints.whiterose.ac.uk/158605/
Hobbs, P. V., and Rangno, A. L. 2004. Super-large raindrops. Geophysical Research Letters 31, doi:10.1029/2004GL020167 (raindrops of at least 8.8 mm observed). https://earthref.org/ERR/82686/
NASA Global Precipitation Measurement Mission. The Anatomy of a Raindrop (drops larger than 4.5 mm become parachute-shaped and break up). https://gpm.nasa.gov/science/anatomy-of-a-raindrop
University of Washington News. 2004. Some of the biggest raindrops on record found in both clean and dirty air (laboratory breakup near 5 mm; in clouds, breakup in collisions with other drops). https://www.washington.edu/news/2004/07/13/some-of-the-biggest-raindrops-on-record-found-in-both-clean-and-dirty-air/
Engine Combustion Network, Sandia National Laboratories. Spray A operating condition (ambient gas density 22.8 kg/m³ at 900 K and about 6 MPa). https://ecn.sandia.gov/?p=76
IAPWS R1-76(2014). Revised Release on the Surface Tension of Ordinary Water Substance, Table 1 (measured: 75.64 mN/m at 0.01 °C, 72.74 mN/m at 20 °C, 58.92 mN/m at 100 °C). https://iapws.org/technical-guidance/release/Surf-H2O.download
Weber Number Formula
The Weber number is a dimensionless ratio of disruptive inertial forces to cohesive surface tension forces:
Where:
- We — Weber number (dimensionless)
- ρ — density of the fluid whose inertia deforms the surface, measured in kg/m³: the surrounding gas for a drop broken up by a gas stream (the gas, or aerodynamic, Weber number); the liquid itself for inkjet drops, drop impact, and the dripping-versus-jetting check of a liquid jet (the liquid Weber number). The wind-induced and atomization regimes of a liquid jet also use the gas density.
- v — velocity, measured in m/s; for drop breakup, the speed of the drop relative to the gas
- L — characteristic length, measured in meters (m): the drop diameter, or the jet or nozzle diameter
- σ — surface tension of the liquid, measured in N/m
For a low-viscosity drop in a gas stream (Ohnesorge number below about 0.1), the critical gas Weber number is about 12. Below it, surface tension keeps the drop intact, though it may flatten or oscillate. Above it the drop fragments: bag breakup up to about 50, bag-and-stamen breakup to about 100, sheet stripping to about 350, then catastrophic breakup (the regimes of Pilch and Erdman; other studies place the boundaries somewhat differently). Computing We with the liquid density instead gives a number about 830 times larger for water in air, and that liquid Weber number cannot be compared with 12.
Worked Examples
Spray Systems
Will a diesel fuel injector atomize fuel into a fine spray?
Diesel fuel (σ = 0.026 N/m) leaves a 0.2 mm nozzle at 200 m/s into hot compressed cylinder gas of about 22.8 kg/m³ (the ambient density of the Engine Combustion Network's Spray A diesel condition: 900 K, about 6 MPa). Jet atomization is judged with the gas Weber number.
- We = ρ_gas × v² × L / σ = 22.8 × 40,000 × 0.0002 / 0.026
- We = 182.4 / 0.026
We ≈ 7,015
Liquid jets atomize once the gas Weber number passes roughly 40 (Reitz's widely used criterion is 40.3), so this jet atomizes at the nozzle. With the fuel's own density (850 kg/m³) you get the liquid Weber number, 261,538, which belongs to other criteria such as dripping versus jetting.
Meteorology
What is the maximum stable raindrop size at terminal velocity?
A large raindrop falls at about 9 m/s through still air (ρ ≈ 1.2 kg/m³); water has σ = 0.0728 N/m. Using the breakup threshold We = 12 (gas density, relative speed), what is the largest diameter that survives?
- L = We × σ / (ρ_air × v²) = 12 × 0.0728 / (1.2 × 81)
- L = 0.8736 / 97.2
L ≈ 0.00899 m (about 9 mm)
A rough estimate: the size scales directly with the critical We you assume (halving it to 6 halves the size to about 4.5 mm). It is close to the largest raindrops ever measured (at least 8.8 mm). In ordinary rain, drops above about 4.5–5 mm distort into a parachute shape and break up, usually after colliding with other drops.
Inkjet Printing
What is the Weber number of an inkjet droplet?
An inkjet nozzle ejects ink (ρ = 1,050 kg/m³, σ = 0.035 N/m) at 8 m/s with droplet diameter L = 0.05 mm. Inkjet work uses the ink's own density (the liquid Weber number). Calculate the Weber number.
- We = ρv²L / σ = 1,050 × 64 × 0.00005 / 0.035
- We = 3.36 / 0.035
We = 96
This liquid Weber number is not compared with the ≈ 12 drop-breakup threshold, which uses the surrounding gas density (with air at 1.2 kg/m³, this drop's gas Weber number is only about 0.11). 8 m/s is inside the 5–10 m/s range printers commonly use to keep drops from splashing. Satellite droplets depend on the ink's viscosity and on drop speed (the Ohnesorge and Reynolds numbers), which this calculator does not include.
Related Calculators
- Cauchy Number Calculator — inertial vs. compressional forces in a fluid
- Euler Number Calculator — pressure drop relative to dynamic pressure
- Cavitation Number Calculator — pressure margin above vapor formation in a flow
- Reynolds Number Calculator — characterize the flow regime alongside surface tension effects
- Density Converter — convert fluid density units used in Weber number calculations
Related Sites
- CameraDOF — Depth of field calculator for photographers
- Z-Score Calculator — Z-score, percentile, and probability calculator
- Dollars Per Hour — Weekly paycheck calculator with overtime
- InfantChart — Baby and child growth percentile charts
- Medical Equations — Hemodynamic, pulmonary, and dosing calculators
- LoanChop — Loan prepayment calculator