Curb Opening Inlet Orifice Equations Formulas Design Calculator


Solving for acceleration of gravity.
acceleration of gravity
Note: equation applies to flow depths greater than 1.4 the opening height

Inputs:

capture flow rate (Qi)
area of opening (A)
flow depth (d)
height of opening (h)

Can you share this page? Because, it could help others.


Conversions:

capture flow rate (Qi)
= 0
= 0
foot^3/second
area of opening (A)
= 0
= 0
foot^2
flow depth (d)
= 0
= 0
foot
height of opening (h)
= 0
= 0
foot

Solution:

acceleration of gravity (g) = NOT CALCULATED

Other Units:


Change Equation
Select to solve for a different unknown
curb type gutter
gutter flow rategutter flow rate
Manning's coefficientManning's coefficient
roadway cross sloproadway cross slope
longitudinal slopelongitudinal slope
flow widthflow width
curb opening inlet with weir operation
requirement
capture flow rate or interception capacitycapture flow rate or interception capacity
curb opening lengthcurb opening length
curb opening widthcurb opening width
flow depth at curbflow depth at curb
curb opening inlet with weir operation
no depression
requirement
capture flow rate or interception capacitycapture flow rate or interception capacity
curb opening lengthcurb opening length
depth of flowdepth of flow
curb opening inlet with orifice operation
capture flow rate or interception capacitycapture flow rate or interception capacity
curb opening areacurb opening area
acceleration of gravityacceleration of gravity
flow depth at curbflow depth at curb
opening heightopening height
gutter opening inlet
capture flow rate or interception capacitycapture flow rate or interception capacity
grate perimetergrate perimeter
flow depthflow depth
slotted pipe drain inlet
pipe length for complete interceptionpipe length for complete interception
flow rateflow rate
longitudinal slopelongitudinal slope
Manning's coefficientManning's coefficient
roadway cross sloperoadway cross slope
gutter capture efficiency
gutter capture efficiencygutter capture efficiency
capture flow ratecapture flow rate
total flow ratetotal flow rate
gutter carryover or bypass
gutter carry overgutter carry over or bypass
total flow ratetotal flow rate
capture flow ratecapture flow rate
Where
Q=gutter flow rate
n=Manning's coefficient
Sx=roadway cross slope
S=longitudinal slope
T=flow width
d=flow depth at curb
a=depressing depth

References - Books:
Martin Wanielista, Robert Kersten and Ron Eaglin. 1997. Hydrology Water Quantity and Quality Control. John Wiley & Sons. 2nd ed.

Infant Growth Charts - Baby Percentiles Overtime Pay Rate Calculator Salary Hourly Pay Converter - Jobs Percent Off - Sale Discount Calculator Pay Raise Increase Calculator Linear Interpolation Calculator Dog Age Calculator Gross Operating Income Calculator Weight Equations Formulas Calculator Circular Motion Equations Calculator Stokes Law Equations Calculator Force Equations Physics Calculator Inflation Rate Equations Calculator Hydraulic Radius Formulas Calculator Ideal Gas Law Calculator Weight Loss Formulas Calculator

Online Web Apps, Rich Internet Application, Technical Tools, Specifications, How to Guides, Training, Applications, Examples, Tutorials, Reviews, Answers, Test Review Resources, Analysis, Homework Solutions, Worksheets, Help, Data and Information for Engineers, Technicians, Teachers, Tutors, Researchers, K-12 Education, College and High School Students, Science Fair Projects and Scientists

By Jimmy Raymond
View Jimmy Rayamond's profile on LinkedIn

Contact: aj@ajdesigner.com

Privacy Policy, Disclaimer and Terms

Copyright 2002-2015